Recent Posts
Recent Comments
Categories
Archives
- December 2019
- November 2019
- March 2019
- February 2019
- January 2019
- March 2018
- February 2018
- January 2018
- November 2017
- October 2017
- August 2017
- January 2017
- November 2016
- October 2016
- September 2016
- July 2016
- June 2016
- May 2016
- March 2016
- February 2016
- January 2015
- December 2014
- November 2014
- October 2014
- September 2014
- July 2014
- May 2014
- April 2014
- March 2014
- February 2014
- December 2013
- November 2013
- October 2013
- June 2013
- February 2013
- January 2013
- December 2012
- September 2012
- July 2012
- May 2012
- April 2012
- March 2012
- February 2012
- October 2011
- June 2011
- April 2011
- March 2011
Tag Archives: DSOX 2002A
SCPI on Mac
Some more days passed and some more finishing touches added to my MacSCPI app. It is entirely dependent on hooking the device via the USBTMC driver, but it works fine and is stable: I had some problems with buffer padding and the output it is still not 100% gibberish–free , but I assume I have to play with …
USBTMC driver for Mac
After some head banging, I finally managed to send SCPI commands from my Mac to my Agilent (Keysight) DSOX2002A. I’ve worked on this since december last year. Almost a year, but I did not spent a sustained amount of effort. I did it just during my free time. I still have a day job that …
C#, SCPI and Keysight (Agilent) DSO-X 2002A
This post is a relic. The initial draft dates back in January 19, 2013. And was left as draft ever since. Past couple of days I was busy — among other things — learning a new programming language, C#. 🙂 Ok, here’s the deal: my scope (KeysightAgilent DSO-X 2002A) is SCPI–compliant device. If you remember, the reason behind …
144.8 Mhz TX for APRS (3)
This is a quick update post. The road I took with this little project is slowly getting to a dead end due to what it seems to be a lack of available crystals for 144.8 (like 48.26 or 28.96 MHz, for using the third or fifth harmonic). I believe that, currently, all APRS modules are …
144.8 Mhz TX for APRS (2)
More work today and yesterday on this project. Still locking on 144 MHz, but this is normal, the crystal I used is a 48 MHz overtoned, working on the third harmonic in this case, thus spot on 144.0 MHz: I managed to clean the output, at the expense of transmitted power. I used a 7-pole 2m bandpass …
144.8 Mhz TX for APRS
Been busy at work lately, but still had some time for myself. Latest idea: a low-cost APRS beacon, done with a classical 144.8 Mhz TX and a μController. AX.25 on air. Automatically. So these days I’ve been busy making this: Winding coils, soldering, measuring. Fun. The frequency is remarkable stable, given the rudimentary nature of this. For example, …
Agilent DSO-X 2002A driver for Mac OS X
Update, October 2nd, 2014: a more recent adavancement in running SCPI on mac, can be found here. Update, December 10th, 2015: Updated terms, changed Agilent to Keysight. December again, another year passed. Traditionally, this is a month when I am taking a long break. But I was up to something in the past days and …
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer’s Guide
Keysight’sAgilent’s InfiniiVision 2000 X-Series Oscilloscopes Programmer’s Guide is highly recommended for anyone interested in remotely controlling KeysightAgilent InfiniiVision 2000 X-Series Oscilloscopes. Via back USB slot. For example: Unfortunately, the [remote] control is limited only to Win PCs. AFAIK. Have to write a review soon about the cool KeysightAgilent Connection Expert, the client app installed together with the KeysightAgilent …
Finally arrived !
I just got it few days ago, a superb brand new Agilent 2002A Digital Storage Oscilloscope. Needless to say that I am absolutely thrilled by this 2G/s 70Mhz baby. It is a perfect addition for my electronics projects. Now I am playing with it, much to discover in the documentation. It comes with a CD …